A step by step guide on how to change the filters
This guidance is for: Commercial Grade models shipped before March '24 which are identifiable by the filtration type. Your Commercial grade unit will have dual filtration with an 80 & 20 micron filter.
For PRO Models shipped after March '24 - head over to the guidance here
The commercial grade bath comes equipped with two filters to keep your bath clean:
The first filter, with a mesh size of 80 microns, is designed to trap larger debris.
The second filter, with a 20 micron particle size, is perfect for capturing smaller particles such as skin, oil, and dirt.
To carry out a filter change, follow these steps:
- Enter maintenance mode by pressing and holding the Ice Boost button for 3 seconds
- Isolate the main filtration unit using the isolation valves by turning the two blue handles 90 degrees clockwise to the of position
- Remove the filter housing by using the provided spanner starting with the one closest to you, and then proceed to remove the plastic filter housings one at a time. Beware you may experience some water loss whilst changing the filter
- Empty the water and dirty filters from the filter housings. You can now clean and sanitise the housings using an anti-bacterial solution
- Rinse the 80 micron mesh filter and refit into the clean filter housing using the green filter locater. This can now be replaced onto the fitting furthest away from you
- Replace the 20 micron particle filter with a clean fresh one and rinse out the used one until clean
- When re-fitting ensure the large O ring on the filter housing is in place and tighten the filter housings with the plastic spanner provided until secure.
- Open the isolation valves again, 90 degrees anti clockwise to the open position.
- Ensure that the filter housing fills with water.
If you require assistance:
Feel free to reach out to our team for support.
Drop us a line by clicking here
Or you can call us on +441135267255 during our operating hours:
Monday to Friday from 09:00am to 17:30pm.