This guidance is for: SPA Grade models which are identifiable by the filtration type. Your SPA grade unit will have a large media filter unit.
-
Turn off chiller fuse spur power supply.
-
Depress and turn filter handle clockwise to waste position. Ensure there is water flow to backwash waste pipe.
-
Depress and turn filter handle clockwise to the backwash position.
-
Wait until the water reduces by 2/3 and 1/3 left in the bath.
-
Depress and turn filter handle anti clockwise to waste position for 20-30 seconds.
-
Turn off bath fuse spur power supply.
-
Turn the blue tap through 90 degrees that is below the water main, note – they are numbered for which plunge you are filling.
-
Turn the water main tap on and fill bath so its halfway to the skimmer in the bath.
-
Once filled – turn water main off first, then turn the blue handle tap (associated with the bath you are filling) to its original position.
-
Turn filter handle anti clockwise to back wash position.
-
Turn bath power back on at fuse spur on back wall.
-
Go to bath and visually check that the light is illuminated, and you can see water flowing inside the bath.
-