Your bath has a control panel in the compartment area.
1 |
Temperature display |
The display has no decimal place therefore - 10 degrees C is displayed as 100. 1 degreesC is displayed as 10. 0.1 degrees C is displayed as 01. |
2 | Temperature down | The lowest temperature setting is 0 degrees C displayed as 00. |
3 | Temperature up |
The highest temperature is 10 degrees C. Note: the bath will not heat up, if you toggle the temperature up it will stop cooling and the water will naturally get warmer. |
4 |
Defrost mode |
If you believe your ice bath has stuck ice on the bottom you can start a manual defrost by pressing and holding the up arrow for 3 seconds. This will release any ice that has accumulated at the bottom of the bath. To exit the defrost mode, simply press and hold the up arrow again. |
6 | Maintenance mode |
Press and hold for 3 seconds to put the bath into a maintenance mode (when you need to change a particle filter). (N.B This button will either be marked ICE BOOST or a SPANNER icon) LED light on the chiller and light in the barrel will flash whilst in this mode. Exit maintenance mode by pressing and holding for 3 seconds again. |
7 | Dip start |
Pressing START will begin a dip session. It switches everything off for a peaceful experience and ensures that any ice on the base of the bath is defrosted. When the light in the bath is solid blue it is safe to get in the bath. If the blue light in the bath is flashing it means a defrost cycle is necessary. This will run for 7-8 minutes and will then revert to solid blue meaning it is now safe to get in the bath.
|
N.B The SPANNER icon replaced the 'ICE BOOST' button on baths shipped from April '24. 'Ice Boost' is a retired function superseded by improved ice cycle software.